Difference between revisions of "Test"
From EG1004 Lab Manual
Jbringardner (talk | contribs) (Blanked the page) |
|||
Line 1: | Line 1: | ||
# Open the file above | |||
# In Hover the mouse over the design and left-click once a blue box surrounds the design. This will highlight every element in the design (Figure 1). | |||
#: [[Image: ___|400px|thumb|center| Figure 1: Highlighting Elements in the Architectural Plan]] | |||
# Select the pin icon under the '''Modify''' tab (Figure 4). This prevents the linked file from being moved. | |||
#: [[Image:___|400px|thumb|center| Figure 2: Pin Icon]] | |||
# Open the L1 - Plumbing floor plan by going to the project browser and expanding the '''Plumbing''' dropdown (Figure 3). | |||
#: [[Image:___|400px|thumb|center| Figure 3: Plumbing Plan in Project Browser]] | |||
# Go to the '''View''' tab, select '''Callout.''' Click and drag over a large area of space containing the bathroom on the first floor (Figure 4). | |||
#: [[Image: ___|400px|thumb|center| Figure 4: Callout of the Bathroom]] | |||
# Go into the callout view by double-clicking on the generated circle | |||
# Select '''Plumbing Fixtures''' under '''Systems''' tab. Under the '''Mode''' tab, select '''Load Family.''' Place a sink, toilet, and shower into the bathroom using the file paths provided in Table 1 below. | |||
:: {|class="wikitable" style="float: center; margin-top: 0px; margin-left:13px;" | |||
|+style="caption-side:bottom; white-space:nowrap;"|Table 1. File Paths. | |||
! '''Components''' !! '''File Paths''' | |||
|- | |||
|Sink || English Imperial → Plumbing → MEP → Fixtures → Sinks → Sink - Work | |||
|- | |||
|Toilet || English Imperial → Plumbing → MEP → Fixtures → Water Closets → Water Closet - Flush Tank | |||
|- | |||
|Shower || English Imperial → Plumbing → MEP → Fixtures → Shower → Shower Stall - Rectangular | |||
|} | |||
<ol start ="8"> | |||
# Make sure the fixtures al aligned to the wall and placed in the correct orientation. Use the spacebar to rotate the fixtures if necessary. | |||
## Note: Make sure that the sink is offset 3 ft off the ground in the '''Properties''' sidebar (Figure 5). | |||
##: [[Image: ___|400px|thumb|center| Figure 5: Properties Sidebar]] | |||
<ol start ="9"> | |||
# Three piping systems can be created: a hot water system, a cold water system, and a sanitary system. In this workshop, only the cold water system will be used. To add pipes, click on a fixture and select the '''Create Pipe''' icon (Figure 6). Choose the cold water icon and not the sanitary icon. | |||
#: [[Image: ___|400px|thumb|center| Figure 6: Create a Pipe Icon]] | |||
# In the properties section, ensure that the pipe is selected as PVC - DWV and set the diameter to 1/2" (Figure 7). |
Revision as of 20:47, 16 September 2024
- Open the file above
- In Hover the mouse over the design and left-click once a blue box surrounds the design. This will highlight every element in the design (Figure 1).
- [[Image: ___|400px|thumb|center| Figure 1: Highlighting Elements in the Architectural Plan]]
- Select the pin icon under the Modify tab (Figure 4). This prevents the linked file from being moved.
- [[Image:___|400px|thumb|center| Figure 2: Pin Icon]]
- Open the L1 - Plumbing floor plan by going to the project browser and expanding the Plumbing dropdown (Figure 3).
- [[Image:___|400px|thumb|center| Figure 3: Plumbing Plan in Project Browser]]
- Go to the View tab, select Callout. Click and drag over a large area of space containing the bathroom on the first floor (Figure 4).
- [[Image: ___|400px|thumb|center| Figure 4: Callout of the Bathroom]]
- Go into the callout view by double-clicking on the generated circle
- Select Plumbing Fixtures under Systems tab. Under the Mode tab, select Load Family. Place a sink, toilet, and shower into the bathroom using the file paths provided in Table 1 below.
Table 1. File Paths. Components File Paths Sink English Imperial → Plumbing → MEP → Fixtures → Sinks → Sink - Work Toilet English Imperial → Plumbing → MEP → Fixtures → Water Closets → Water Closet - Flush Tank Shower English Imperial → Plumbing → MEP → Fixtures → Shower → Shower Stall - Rectangular
- Make sure the fixtures al aligned to the wall and placed in the correct orientation. Use the spacebar to rotate the fixtures if necessary.
- Note: Make sure that the sink is offset 3 ft off the ground in the Properties sidebar (Figure 5).
- [[Image: ___|400px|thumb|center| Figure 5: Properties Sidebar]]
- Note: Make sure that the sink is offset 3 ft off the ground in the Properties sidebar (Figure 5).
- Three piping systems can be created: a hot water system, a cold water system, and a sanitary system. In this workshop, only the cold water system will be used. To add pipes, click on a fixture and select the Create Pipe icon (Figure 6). Choose the cold water icon and not the sanitary icon.
- [[Image: ___|400px|thumb|center| Figure 6: Create a Pipe Icon]]
- In the properties section, ensure that the pipe is selected as PVC - DWV and set the diameter to 1/2" (Figure 7).